3 modem to pc serial connection, Entraguard, Platinum telephone entry controller – Keri Systems EntraGuard Platinum Quick Start User Manual

Page 19: Quick start guide

Advertising
background image

EntraGuard

®

Platinum Telephone Entry Controller

Quick Start Guide

Page 19 of 28

P/N: 01969-001 Rev. C

6.2.3

Modem to PC Serial Connection

Keri Systems does not provide this cable. It is an off-the-shelf item from any computer supplier or electronics store, and
its configuration is dependent upon the configuration of the serial port on the host computer. Based on the serial port, there
are four possible cables.

If the modem has a male DB-25 connector and the host computer’s serial port has a female DB-9 connector, purchase
or create a cable as shown in Figure 22.

If the modem has a male DB-25 connector and the host computer’s serial port has a female DB-25 connector,
purchase or create a cable as shown in Figure 23.

If the modem has a male DB-9 connector and the host computer’s serial port has a female DB-9 connector, purchase
or create a cable as shown in Figure 24 on page 20.

If the modem has a male DB-9 connector and the host computer’s serial port has a female DB-25 connector, purchase
or create a cable as shown in Figure 25 on page 20.

NOTE: Keri Systems requires using modems from the same manufacturer at both the host computer and the access control
network. This eliminates the possibility of incompatibilities between modems from two different manufacturers from
affecting the communication between access control network and host computer. Keri Systems cannot be held responsible
for problems caused by incompatibilities between modems from two different manufacturers.

Figure 22: Modem/DB-25M to PC/DB-9F PC Serial COM Port Connection

Figure 23: Modem/DB-25M to PC/DB-25F PC Serial COM Port Connection