8.1

Set Unit Address

The controller’s address may only be set through the Reset Menu. To set the desired operating address for the controller,
press 1 on the keypad. The Set New Unit Address screen appears on the LCD (see Figure 28).

Figure 28: Set Unit Address

The address range is from 1 to 128. The Master Controller must be set to address 1. Other slave EntraGuard/PXL-500/510
controllers may be assigned any number from 2 to 128. If the network is made up of PXL-250s, the EntraGuard Platinum
must be set as the Master.

If the address shown as Current is correct, you may either enter the same address and press *, or just press * to return to
the reset menu. If you do not enter a new address, or enter the same address that is already assigned to this unit, you will
need to clear the memory separately (see “Clear the Controller’s RAM’’ on page 24).

NOTE: Changing the address of an EntraGuard Platinum controller completely erases all information within the
controller. It is vitally important that you collect all data from the controller before changing the address. Once the
address is changed (and the RAM is automatically cleared) the information in the controller is lost and cannot be
recovered.

If the address shown as Current needs to be changed, enter the new address by pressing the numbers on the keypad. The
number selected will show in the New line. If you enter the wrong number, simply press CLEAR to erase what has been
entered. When you are satisfied with the address entered, press *. If you have changed the number from what is shown as
Current, the controller will automatically clear the memory as it changes the address (see Figure 29).

Figure 29: Setting New Address

Once the memory has been cleared, the unit is ready to be configured. The LCD will display a warning that the unit has
not been initialized (see Figure 30 on page 24). This display will rotate with the EntraGuard Default display (see Figure
31 on page 24) u
ntil a Total Update from Doors has been performed on the unit. Once an update has been performed, only
the default will be displayed.