Wiring Instructions

Refer to Figure 2 on page 2 for all wiring connections.

5.1

Terminal Blocks

Figure 5: Connecting Wires and Removing Terminal Blocks

NOTE: Screws on terminal blocks must be tightened securely.

5.2

Connecting the Earth Ground and the 12 VDC Power

The EntraGuard Platinum panel requires 12 VDC power at 750 mA. You must make a quality earth ground connection to
the controller prior to connecting the DC power lines. The earth ground provides protection for the controller and ensures
the best possible operating conditions. Possible sources for earth ground are a ground rod, a cold water pipe, a steel
building frame, the electrical system ground at the breaker/fuse box, or the telephone system ground. The earth ground
connection should be located as close as possible to the EntraGuard Platinum controller. Use the information in Table 1
and Figure 6 to mak
e the earth ground and power connections.

Figure 6: Earth Ground and 12 VDC Power Connections

NOTE: The grounding wire should be a minimum of 14 gauge.

Table 1: Earth Ground and Power

Connections

TB-2 Pin

Description

1

+ 12 VDC Power Line

2

- 12 VDC Power Line

3

Earth Ground