Site global secure time, Site global unlock enable, Site comment – Keri Systems Doors16 User Manual

Page 184

Advertising
background image

Doors™ Users Guide

Keri Systems, Inc.

October 1998

01821-001

Page 184

Revision 2.1

Figure 173 – Entering Sites Data, Part 2

Site Global Secure Time

The global secure time field allows an operator to enter a time-of-day when all doors in the
access control network should be locked. This ensures that regardless of the door status during
the day, all doors in the access control network are locked at least once a day.

NOTE: All times are formatted to a 24-hour clock. For example, 5:30 P.M. is 17:30 under the
24-hour clock.

1.

Click on the "Global Secure Time" cell for the site (see Figure 173).

2.

Type the global secure time for the site. For example, the global secure time for this site
should be 22:30 hours (10:30 P.M.); type 22:30.

Site Global Unlock Enable

The global unlock enable button allows an operator to program general purpose input #1 on
the master controller such that an active signal on the input immediately unlocks all doors on
the access control network. General purpose input #1 is a normally-open input. To activate
this input, the input terminals must be closed (shorted together).

1.

To enable the global unlock input, click on the OFF button. The OFF button will toggle
to ON and its color will change from red to green (see Figure 173).

2.

To disable the global unlock input, click on the ON button. The ON button will toggle to
OFF and its color will change from green to red (see Figure 173).

Site Comment

The site comment field allows an operator to enter a comment regarding the site.

1.

Click on the "Comment" cell for the site (see Figure 173).

2.

Type a brief comment about the site. For example, the Manufacturing and Sales site is the
home office for the company; type Home Office - Mfg and Sales.

Based on the remaining parameters, the database for the Mfg - Sales site should look similar
to Figure 174.

Advertising