1.2 Model Identification

Consult the rating plate on the unit. The

following information describes the model number

structure.

Model Character Designation

1-2 Model Series Designation

M S = Mighty Stack

3-5 Gallons

080 = 80 Gallons (303 liters)

5-8 Size

1 9 9 = 199,900 BTU/h input

3 0 0 = 299,000 BTU/h input

3 9 9 = 399,900 BTU/h input

9 Fuel

N = Natural Gas

P = Propane

10 Altitude

A = 0-10,000 feet

11 Heat Exchanger / Tank Approvals

2 = HLW Copper Heat Exchanger Only

5 = HLW Cupronickel Heat Exchanger Only

X = HLW (Tank and Copper Heat Exchanger)

Y = HLW (Tank and Cupronickel Heat Exchanger)

12 Pump

N = Normal Water Pump

S = Soft Water Pump

13 Model Revision

1 = Initial Release

1.3 Warranty

Laars Heating Systems’ Mighty Stack appliances

are covered by a limited warranty. The owner should

go to the Laars.com website and register for warranty.

All warranty claims must be made to an

authorized Laars Heating Systems representative or

directly to the factory. Claims must include the serial

number and model (this information can be found

on the rating plate), installation date, and name of

the installer. Shipping costs are not included in the

warranty coverage.

Some accessory items are shipped in separate

packages. Verify receipt of all packages listed on

the packing slip. Inspect everything for damage

immediately upon delivery, and advise the carrier of

any shortages or damage. Any such claims should be

filed with the carrier. The carrier, not the shipper, is

responsible for shortages and damage to the shipment

whether visible or concealed.

1.4 Dimensions

See Figure 1.

1.5 Locating the Appliance

The appliance should be located to provide

clearances on all sides for maintenance and inspection.

It should not be located in an area where leakage of

any connections will result in damage to the area

adjacent to the appliance or to lower floors of the

structure.

When such a location is not available, it is

recommended that a suitable drain pan, adequately

drained, be installed under the appliance.

The appliance is design certified by CSA-

International for installation on combustible flooring;

in basements; in closets, utility rooms or alcoves.

Mighty Stack Water heaters omust never be

installed on carpeting. The location for the appliance

should be chosen with regard to the vent pipe lengths

and external plumbing. The unit shall be installed

such that the gas ignition system components are

protected from water (dripping, spraying, rain, etc.)

during operation and service (circulator replacement,

control replacement, etc.). When vented vertically, the

Mighty Stack must be located as close as practical to

a chimney or outside wall. If the vent terminal and/

or combustion air terminal terminate through a wall,

and there is potential for snow accumulation in the

local area, both terminals should be installed at an

appropriate level above grade such that blockage of

the terminal from accumulated debris or precipitation

is prevented.

The dimensions and requirements that are shown

in Table 2 should be met when choosing the locations

for the appliance.

1

2

3

4 5

6

7 8

9

10

11

12

13

M S

0

8 0

A

SERIES

M

S

GALLONS

0 8 0

SIZE

1

9

9

3

0

0

3

9

9

FUEL

N
P

ALTITUDE

A

REVISION

1

HEAT

EXCH.

2
5

X
Y

PUMP

OPTIONS

N
S

Model Nomenclature

see Section 1.2 for Model Identification

Advertising