Combustion System Replacement Procedure

Step 1.

Fully inspect burner mounting insert gasket for the following:

a) Tears

d) Dirt or debris

b) Missing material

e) Other imperfections that would inhibit proper seal

c) Cracks

If gasket is NOT affected by any of the above, gasket replacement is not required.

Step 2.

Install combustion assembly using new gasket or fully inspected gasket from step 1.

Secure combustion assembly at the burner mounting insert using screws from step 6

on previous page. Tighten screws evenly.

Step 3.

Reconnect wire harnesses to hot surface igniter, flame sensor, blower and gas valve.

Step 4.

Reconnect PVC venting, gas supply and silicone tubing to gas valve. Turn on gas

supply to heater and check for gas leaks, repair any gas leaks found.

Step 5.

Restore 120 volt power supply to water heater and confirm proper operation following

the lighting instructions on the lighting instruction label or the lighting instruction located

in the installation and operating instruction manual.

Step 6.

Replace surround cover on top of water heater.

Gas valve

wire harness

Gas

connection

PVC vent

connection

Burner mounting

insert

Burner mounting

screw

(Total of 5)

Burner tube

Burner mounting

insert gasket