Page 36

Reset heater, observe

heating cycle. Does

switch open?

Y

Does switch open prior

to 350°F?

DO NOT OPERATE

HEATER

System over heating,

immediately contact

technical support.

N

Locate harness

connection.

(see photo at right)

Y

Is there continuity

Through GREY

Lead wires of heater side

harness?

(see photo at right)

N

Replace vent

safety switch

(see page 37)

Call technical

support.

Y

N

Depress reset

button on high

limit switch. Is

there continuity

across high limit

switch?

(see photo below)

Does heater

function?

N

Y

Is temp over 350°F?

Y

N

Sequence of operation:

With the thermostat calling for heat, prior to energizing blower, the ignition module checks the vent safety switch for normal

switch position of normally closed. If the vent safety switch contacts are open, (not in normal position), the ignition module waits

indefinitely for contact to close, The vent safety switch must be manually reset to close the switch contacts.

System OK

N

Y

Replace vent safety

switch

(see page 37)

Heater side

harness

Control side

harness

WARNING

120 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

Reset button

36

WARNING

Make sure exhaust collector compartment is not

overheating (350°F) before resetting vent safety

switch. If there is evidence the collector compartment

is overheating, CALL TECHNICAL SUPPORT.