LABEC GW1060 User Manual

Page 39

Advertising
background image

Rev. 00

GW2045 – GW1060 Manual

Pag. 38 di 43

ALARM ID

DESCRIPTION

ACTION

22

The cold water flowmeter does not
measure correctly.

Check the water supply (taps, pressure, connections to
pipes etc), repeat programme.

23

Insufficient water.

Check the water supply (taps, pressure, connections to
pipes etc).

24

Lack of water.

Check the water supply (taps, pressure, connections to
pipes etc).

25

Insufficient pressure in the circulating
motor pump.

Possible presence of foam in vat.
Check the type of detergent used.
Repeat the cycle.

29

No draining.

Check the outlet connection.

30

Water safety level.

Repeat the cycle. Call the Technical Assistance Service if
the fault persists.

31

Safety level fault.

Repeat the cycle. Call the Technical Assistance Service if
the fault persists.

32

Standing water in the washing
chamber.

Reset. Repeat the cycle. Call the Technical Assistance
Service if the fault persists.

33

OFF

34

OFF

35

OFF

36

OFF

52

Door is electrically open.

Check that the door is closed before proceeding with a
programme cycle.

Open and close the door. Check the condition of the
micro-switch that detects closing. Call the Technical
Assistance Service if the fault persists.

54

Door is mechanically open.

Check that the door is closed before proceeding with a
programme cycle. Call the Technical Assistance Service
if the fault persists.

56

Door lock fault.

Check that the door is closed before proceeding with a
programme cycle. Call the Technical Assistance Service
if the fault persists.

73

Cycles archive is full.

Error within the microprocessor. These are overwritten
one at a time once the cycles archive becomes full.

Call the Technical Assistance Service if the fault persists.

77

Inlet water temperature higher than
45°C, prewashing must be carried
out at temperatures below 45°C.

The alarm trips when the temperature at the start of the
cycle is greater than 45°C.

Wait for the machine to cool before starting a new cycle.

78

Microprocessor failure.

Error within the microprocessor.
Call the Technical Assistance Service if the fault persists.

81

Demineralised water inlet problem –
not active.

Check the water supply:

!

Tap open

!

Inlet water pressure

!

Absence of narrowing in connection pipe).

!

Check the condition of the demineralised water
turbine.

Repeat the cycle, the malfunction may be temporary.

82

Door lock coil fault.

Repeat opening. Call the Technical Assistance Service if
the fault persists.

The active alarm in the door opening phase: If, after a
series of opening impulses, the door remains closed,
intervene. Check that the solenoid run is not blocked and
that the opening piston on the side of the vat releases
correctly.

94

Unstable temperature

This malfunction can be temporary: Repeat the cycle.
Check that the temperature probe is functioning properly.

Advertising