17

Preventive Maintenance

1. Remove dirt and road debris from jacks and stabilizer

struts (if equipped) as needed.

2. If jacks are down for extended periods, it is

recommended to spray exposed leveling jack tubes

with a spray lubricant every 3 months for protection.

If the coach is located in a salty environment, it is

recommended to spray the rods every month.

LCD

Message

What's Happening? What Should Be

Done?

***ERROR***

LF Jack

RF Jack
LR Jack

RR Jack

Error at a specifi c jack (left

front, right front, left rear,

right rear). Hall signal issue

(open, short, malfunction).

Check harness

connections at controller

and at jack.
Check harness for

damage.
Repair or replace as

necessary.

Unexpected high amp current

stall.

Special Jack Error Codes

NOTE: To clear one of these errors:
1. Correct or otherwise repair the issue (see the table below).
2. Extend all of the jacks at least six (6) inches, then press

and hold the “RETRACT” button on the touch pad until the

jacks begin retracting.

3. All of the jacks will retract fully to clear the error.

Ensure the coach is supported at both the front

and rear with jack stands before performing any

troubleshooting or service to the unit. Failure to

do so may result in death or personal injury.

Notes