Chamberlain ESTATE SERIES SW 2000-X3 User Manual

Page 17

Advertising
background image

Rev

M

F

Doc

01-20099

11

of

42

I. SETTING LIMIT CAMS

• Adjust the limit cams by loosening the clamp and rotating the cams. The cams

rotate with the swing arm shaft, so small adjustments are magnified by the length
of the gate.

• Use manual controls to move the gate during limit cam adjustment.
• To avoid damage to the gate and gate operator due to the gate overrunning its

limits, perform the following steps carefully:

1. SETTING RIGHT GATE LIMIT CAMS

Top Limit Switch

Bottom Limit Switch

Top Limit Cam

Bottom Limit Cam

Open Gate

Closed Gate

01-20099F1

Figure 8. Setting Right Gate Limit Cam

1. Make sure that switch S2 is set to the "Right" position.
2. Turn on gate operator power switch.
3. Using manual CLOSE and STOP, move the gate to its proper closed limit position.
4. Loosen the clamp on the bottom limit cam and turn the cam clockwise until it just

barely closes the limit switch.

5. Retighten the clamp. Do not overtighten.
6. Using manual OPEN and STOP, move the gate to its proper open limit position.
7. Loosen the clamp on the top limit cam and turn the cam counterclockwise until it

just barely closes the limit switch.

8. Retighten the clamp. Do not overtighten.
9. Open and close the gate to check the limit cam settings. If required, readjust the

limit cams until they are set properly.

Advertising