J. GATE SENSITIVITY ADJUSTMENTS

The gate operator monitors both average and peak motor current. When the gate
encounters an obstruction, the gate operator senses the change in motor current and
reverses the gate. Three sensitivity adjustments must be set for each installation:

• Right gate motion (R69)

• Left gate motion (R160)

• Inrush current (R203)

NOTE: For swing gate operation, controls are Left/Clockwise and
Right/Counterclockwise.
♦ If your installation requires setting switch S2 to the “Open to Right” position, use

the “Open to Right" adjustment procedures below. If your installation requires
setting S2 to the “Open to Left” position, use the “Open to Left" adjustments
following the "Open to Right" procedures.

♦ The minimum sensitivity is full clockwise and maximum sensitivity is full counter

clockwise. These adjustments must be made while the gate is in motion.

♦ Before starting the adjustments, verify that the Left and Right reverse pots are set

fully clockwise, and the Inrush pot is set to the 11 o’clock position.

♦ Make all adjustments in the order listed.
NOTE: Current flow varies with temperature. Do not tune the sensitivity
measurements too finely, or they may cause false overcurrent faults to occur during
cold weather.

Figure 10. Gate Sensitivity Adjustments Location.

"OPEN TO RIGHT" ADJUSTMENT PROCEDURES

Right Gate Motion Adjustment (R69)
1. Initiate opening the gate.
2. Wait 4 to 5 seconds, then lightly "tug" against the edge of the gate to simulate an

obstacle.

3. If the gate does not stop or back up, reclose gate and adjust the pot slightly

counterclockwise.

4. Repeat steps 1-3 until gate stops or backs up when tugged and has the desired

sensitivity.

Advertising