Left Gate Motion Adjustment (R160)
1. Open the gate fully, then initiate closing the gate.
2. Wait 4 to 5 seconds, then lightly "bump" the leading edge of the gate to simulate

an obstacle.

3. If the gate does not stop or back up, reopen the gate and adjust the pot slightly

counterclockwise.

4. Repeat steps 1-3 until the gate stops or backs up when bumped and has the

desired sensitivity.

"OPEN TO LEFT" ADJUSTMENT PROCEDURES

Left Gate Motion Adjustment (R160)
1. Initiate opening the gate.
2. Wait 4 to 5 seconds, then lightly "tug" against the edge of the gate to simulate an

obstacle.

3. If the gate does not stop or back up, reclose the gate and adjust the pot slightly

counterclockwise.

4. Repeat steps 1-3 until the gate stops or backs up when tugged and has the

desired sensitivity.

Right Gate Motion Adjustment (R69)
1. Open the gate fully, then initiate closing the gate.
2. Wait 4 to 5 seconds, then lightly "bump" the leading edge of the gate to simulate

an obstacle.

3. If the gate does not stop or back up, reopen the gate and adjust the pot slightly

counterclockwise.

4. Repeat steps 1-3 until the gate stops or backs up when bumped and has the

desired sensitivity.

INRUSH CURRENT ADJUSTMENT (R203)

1. Turn the pot fully counterclockwise.
2. Open the gate.
3. If the gate stops due to a fault condition, slightly adjust the pot clockwise.
4. Repeat steps 2 and 3 until the gate cycles without a fault.
5. Open gate fully, then initiate closing the gate.
6. If the gate stops or backs up due to a fault condition, slightly adjust the pot

clockwise.

7. Repeat steps 6 and 7 until the gate cycles without a fault and has the desired

sensitivity.