2. SETTING LEFT GATE LIMIT CAMS

Top Limit Switch

Bottom Limit Switch

Top Limit Cam

Bottom Limit Cam

Open Gate

Closed Gate

01-20099F2

Figure 9. Setting Left Gate Limit Cam

1. Make sure that switch S2 is set to the "Left" position.
2. Turn on gate operator power switch.
3. Using manual OPEN and STOP, move the gate to its proper open limit position.
4. Loosen the clamp on the bottom limit cam and turn the cam clockwise until it just

barely closes the limit switch.

5. Retighten the clamp. Do not overtighten.
6. Using manual CLOSE and STOP, move the gate to its proper closed limit position.
7. Loosen the clamp on the top limit cam and turn the cam counterclockwise until it

just barely closes the limit switch.

8. Retighten the clamp. Do not overtighten.
9. Open and close the gate to check the limit cam settings. If required, readjust the

limit cams until they are set properly.