minimum drive

#6 MINIMUM DRIVE SETTINGS

(1 of 10)

BLUE & YELLOW LEDs

Amount of forward drive applied with first pulse of transmitter throttle information.
>> Increasing this setting starts the forward drive at a stronger level.
This is useful to compensate for heavier vehicles to minimize the

amount of trigger throw required before effective drive is applied.

Setting

(# of flashes)

1

2

3

4

5

6

7

8

9 10

Minimum Drive (%):

0

1

2

3

4

6

8 10 12 15

dead band

#7 DEAD BAND SETTINGS

(1 of 5)

BLUE & RED LEDs

The space between Minimum Brake and Minimum Drive, with Neutral in the middle.
>> Increasing this setting increases amount of ‘free play’, or distance the

transmitter’s trigger must move before forward drive or braking begins.
This is useful for triggers that don’t center accurately or have worn pots.

Setting

(# of flashes)

1

2

3

4

5

Dead Band (%):

2

3

4

5

8

reverse

#8 DRIVE/BRAKE MODE SELECTION

(1 of 2) BLUE & GREEN LEDs

>> Changing this setting activates or deactivates the ESC’s motor

reversing functionality. When OFF, the ESC has forward and brakes

only. When ON, the ESC has forward with brakes, then reverse with

a second push of trigger after braking to a slow speed.

Setting

(# of flashes)

1

2

Reverse:

OFF

ON

motor rotation

#9 MOTOR ROTATION SELECTION

(1 of 2) BLUE & WHITE LEDs

>> Changing this setting changes the rotational direction of the

motor’s output/pinion shaft. Counter-clockwise rotation is the

standard in most remote control vehicles. For optimal motor

performance, use counter-clockwise rotation instead of reversing the

transmitter’s throttle channel throw.

Counter-clockwise rotation is standard in most vehicles.

Note:

Novak Spec & Mod motors come factory-timed to 30° timing

and are optimized for primarily forward-only operation when the

motor is operating in the CCW rotation.

Setting

(# of flashes)

1

2

Rotation Direction:

CCW

Q

CW

P

voltage cut-off

#10 VOLTAGE CUT-OFF

(1 of 2)

BLUE-YELLOW-RED-GREEN LEDs

>> Changing this setting enables or disables the built-in Auto-Detect

Smart Stop voltage cut-off circuitry, and also sets the voltage cut-off

point based on the number of cells in the vehicle’s main battery pack.

DO NOT USE LiPo BATTERIES WITH THE ESC’S

VOLTAGE CUT-OFF CIRCUITRY TURNED OFF

Setting

(# of flashes)

1

2

Voltage Cut-Off Type:

OFF

(NiMH/NiCd)

LiPo

trans/reciever rate

#11 RECEIVER RATE SELECTION

(1 of 2)

RED & GREEN LEDs

>> Selects type of transmitter/receiver rate ESC will work with.

Setting

(# of flashes)

1

2

Radio System Mode:

M12 SSR MODE

STD RATE Rx MODE

hall sensor test

#12 MOTOR SENSOR TEST

Blinking BLUE LED

>> This is a diagnostic feature that allows you to easily check the

functionality of your brushless motor’s hall effect sensors & sensor

harness and its connections at the speed control and motor. Once

activated, slowly rotate the motor’s output/pinion shaft and the

appropriate LED will light up if a signal is received for its sensor

in the motor. Refer to ‘MOTOR HALL SENSOR TEST’ section.

Motor Hall Sensor

A

B

C

LED Color:

BLUE

YELLOW

RED

restoring factory defaults

Every time the speed control’s

One-Touch Programming is performed,

the ESC will automatically revert back

to the factory default settings.