Brushless profile programming, Throttle profile, Drag – Novak Brushed Speed Control: Eiger & Eiger Pro Field Guide-- NEW version ESCs (standard height heat sinks) (55-1835P-1.4) User Manual

Page 3: Hill brake, Brake frequency, Drive frequency, Dead band, Minimum drive, Motor rotation, Voltage cut-off

Advertising
background image

brushless profile

programming

throttle profile

#1 THROTTLE PROFILE SELECTION

(1 of 2) BLUE-RED-WHITE LEDs

>> Changing this setting switches the ESC’s motor control output.

To use with a Sensor-Based Brushless Motor, change to Setting #2 .

Note: When performing One-Touch Set-Up (page 1), be sure to leave the brushless

motor wires DISCONNECTED. After the One-Touch Set-Up is done, change the

Throttle Profile Setting to #2, then connect the brushless motor power wires.

Setting

(# of flashes)

1

2

Throttle Profile:

Brush

Brushless

drag

/

hill brake

#2 DRAG/HILL BRAKE SETTINGS

(1 of 10) BLUE LED

Amount of braking being applied while transmitter is at neutral. AKA ‘hold’ brakes.
>> Settings 1-5 are Standard Drag Brake settings--less aggressive
braking for rock racing (setting #1 applies no braking while trigger is
at neutral)
.
Settings 6-10 are Power Hill Brake settings (ESC applies power to mo-
tor to ‘hold’ its position)
--very strong rock crawling Hill/Hold braking.
Note: you must have a Novak Crawler brushless motor to have power brakes.

Setting

(# of flashes)

1

2

3

4

5

6

7

8

9 10

Drag Brake (%):

0

40 60 95 100 40 65 70 80 90

Brake Type:

Drag Brakes

Power Hill Brakes

BRAKE FREQUENCY

#3 BRAKE FREQUENCY SELECTION

(1 of 10) RED LED

How the ESC’s braking response feels with respect to the transmitter’s trigger input.
>> Increasing the Brake Frequency makes the brake response feel

smoother and more controllable.

Setting

(# of flashes)

1

2

3

4

5

6

7

8

9 10

BrakeFreq.

(KHz)

:

13.5 10.5 5.5 4.5 3.5 3 2.5 2.25 2 1.6

DRIVE FREQUENCY

#4 DRIVE FREQUENCY SELECTION

(1 of 10) BLUE & WHITE LEDs

How the ESC’s throttle response feels with respect to the transmitter’s trigger input.
>> Increasing the Drive Frequency makes the throttle response feel

smoother and more controllable.

Setting

(# of flashes)

1

2

3

4

5

6

7

8

9

10

Drive Freq.

(KHz)

:

32 30 25 23 21 16 14 12 10

8

dead band

#5 DEAD BAND SETTINGS

(1 of 5) BLUE-YELLOW-RED LEDs

Dead Band is the space between Minimum Brake and Minimum Drive, with

Neutral in the middle.
>> Increasing this setting increases amount of ‘free play’, or distance

the transmitter’s trigger must move before the ESC sends forward

drive or braking signal to the motor.
This is useful for transmitters with triggers that don’t center accurately

or have worn pots and do not return to neutral properly.

Setting

(# of flashes)

1

2

3

4

5

Dead Band (%):

2

3

4

5

8

minimum drive

#6 MINIMUM DRIVE SETTINGS

(1 of 10) BLUE-YELLOW-GREEN LEDs

Minimum Drive is the amount of forward drive applied with first pulse of transmit-

ter throttle information sent.
>> Increasing this setting starts the forward drive at a stronger level.
This is useful to compensate for heavier vehicles to minimize the

amount of trigger throw required before effective drive is applied.

Setting

(# of flashes)

1

2

3

4

5

6

7

8

9 10

Minimum Drive (%):

0

1

2

3

4

6

8 10 12 15

motor rotation

#7 MOTOR ROTATION SELECTION

(1 of 2) BLUE-GREEN-RED LEDs

>> Changing this setting changes the rotation direction of the motor’s

output/pinion shaft. Counter-clockwise rotation is standard in most

vehicles.

Setting

(# of flashes)

1

2

Rotation Direction:

CCW

Q

CW

P

Note: Your brushless motor must have the mechanical timing set to 30° for

proper operation in forward and reverse direction. All Novak brushless motors,

except for Novak Crawling motors, are factory timed to 30°. To change the

mechanical timing on your Novak motor, refer to the Novak website (www.

teamnovak.com) in the TECH INFO section. Having the motor set at 0° will

draw excessive current in the reverse direction and may cause damage.

VOLTAGE cut-off

#8 VOLTAGE CUT-OFF

(1 of 3) BLUE-YELLOW-GREEN-RED LEDs

>> Changing this setting enables or disables the ESC’s built-in Smart

Stop cut-off circuitry, and also sets the voltage cut-off point based on

what type of battery is being used for the vehicle’s main battery pack.

DO NOT USE LiPo/LiFe BATTERIES WITH THE ESC’S

VOLTAGE CUT-OFF CIRCUITRY TURNED OFF

Setting

(# of flashes)

1

2

3

Voltage Cut-Off Type:

OFF

(NiMH/NiCd)

LiPo

LiFe

hall sensor test

#9 MOTOR SENSOR TEST BLINKING BLUE LED

>> This diagnostic feature allows you to check the functionality of

your brushless motor’s hall effect sensors & sensor harness

(and its

connections at the ESC and motor). Once activated, slowly rotate the mo-

tor’s output/pinion shaft and the appropriate LED will light up if a

signal is received for that sensor in the motor. Refer to ‘MOTOR HALL

SENSOR TEST’ section.

Motor Hall Sensor

A

B

C

LED Color:

BLUE

YELLOW

RED

restoring factory defaults

Every time the ESC’s One-Touch Set-Up is

performed, the ESC will automatically revert

back to the factory default settings.

For brushless motors, be sure the power wires are disconnected

before One-Touch Set-Up is performed.

Note: ESC Parameter values are subject to change due to ongoing development.

P3

Refer to our web site for updated values and more information on ESC parameters.

Advertising