Table 3-1

lists the system specifications for the Cisco CRS 8-slot LCC with a fixed configuration power

system installed.

Table 3-1

8-Slot Line Card Chassis Component and Power Specifications—Fixed Configuration
Power

Description

Value

Supported Cards and Modules

8 modular services cards (MSCs) or forwarding
processor (FP) cards (line cards)

8 physical layer interface modules (PLIMs),

one for each MSC or FP

4 switch fabric cards (SFCs)

2 route processors (RP) cards or performance route
processor (PRP) cards

1 distributed route processor (DRP) card (no dedicated
slot; installs in open MSC slot)

2 fan trays (with four fans per fan tray)

1 air filter

Power Distribution Units

2 AC (Wye or Delta) or 2 DC power distribution units
(PDUs)

(cannot mix AC and DC PDUs in the chassis)

DC PDU

Supports 1 DC power entry module (PEM)

AC PDU

Supports 1 AC rectifier module