4

WARNING

Electrical shock hazard. To prevent electrical shock, death or equipment damage, disconnect power supply before
installing or servicing this control.

WIRING TO IGNITION CONTROL MODULE

TO

INDIRECT

WATER

HEATER

FROM

THERMOSTAT

INPUT ON

CONTROL

MODULE

#45-531-56

Wire

Harness

For use on boilers equipped with Integrated Boiler Control Module

CABLE 1 — ቢ Disconnect boiler wire Harness from the “SECONDARY” port on the Integrated Control Module

and ባ plug into female plug adapter on #45-531-56 Wire Harness. ቤ Plug male adapter on #45-531-56 Wire

Harness into “SECONDARY” port on the Integrated Control Module. ᕆ Plug the other end of the Wire Harness

into the Model 3000 Low Water Cut-Off. ᕇ Connect the yellow wires in series with Limit Circuit.
CABLE 2 — ቨ Plug Wire Harness into the Model 3000 Low Water Cut-Off. ቩ Connect the two YELLOW wires

to the end switch from the indirect water heater relay. NOTE: If you are not connecting to an indirect water heater,

the bare ends of the YELLOW wires must be capped off separately with wire nuts. ቪ Connect the RED and WHITE

wires in parallel to wiring from the thermostat input on the control module and the existing thermostat wiring.