Program mode, 1 program entry points, 1 alternative 1 – program at start up – Soniclean UW3000 User Manual
Page 13: 2 alternative 2 - program during operation, 2 program parameters

De-gas
De-gassing removes air bubbles from the water prior to
ultrasonic cleaning.
Red light indicates de-gas is operating.
Press DE-GAS during the degas cycle to cancel the current
operation.
Prog
Places the machine in program mode to allow alterations to the
programmed settings.
Hold down SHIFT key then press PROG key and hold for 3
seconds.
Test
Operates the ultrasonic cleaning mode for 30 seconds for the
foil test.
Clean
Values
Cleaning times and power levels may be changed without
performing the complete programming procedure.
8. Program Mode
The parameters can be altered by entering the program mode. There are 3
ways of entry to this mode.
8.1 Program Entry Points:
8.1.1 Alternative 1 – Program at Start Up
i)
Press the “PROG” key then turn on the machine.
ii)
Hold the “PROG” down until the machine displays “Ct.nn”.
iii)
Release the “PROG” key.
8.1.2 Alternative 2 - Program during Operation:
i)
When the machine will display “- - . - -“
ii)
Hold down the “SHIFT” key and then press the “PROG” key and hold for
3 seconds.
8. Alternative 2 - Program during Operation:
i) When the machine will display “- - . - -“
ii) Hold the “Program” key for 3 seconds
iii) Ct, PO & rt parameters may be reset.
iv) Values will be held until changed or until machine is restarted.
8.2 Program Parameters:
To program the parameters, enter program mode as desired in 8.1, then:
i)
The machine will display a variety of parameters that may reconfigure.
ii)
Press the arrow “UP” key to increase the parameter and the arrow
“DOWN” key to decrease the parameter.
i)To accept a value press “ENTER”. The display will scroll through to the next
parameter.
ii)Refer the tables below for parameters and values.
UW-3000 Washer Operating Manual
Page 13 of 24
© Soniclean Pty Ltd
Version 2.0
April 2009