UW-3000 Ultrasonic Washer INSTRUCTIONS

UW-3000 Washer Operating Manual

Page 21 of 24

© Soniclean Pty Ltd

Version 2.0

April 2009

SUMMARY OPERATING INSTRUCTIONS

●

Remove tray. Turn on at power point. Machine will display 8.8.8.8, then SC4.1. Machine will

automatically drain, flush, drain the flush, fill, & degas (approx. 2+3+20=25 minutes)
●

Machine will display

- - - -

●

Check program settings.

●

The machine is now ready for use.

●

Load the machine and Close the lid.

●

Press CLEAN. Display shows C-01 (number of cleans), degas, 01.52 (time remaining), then C-01

(number of cleans), P-03 (power level), 09.48 (time remaining)
●

To stop cleaning at any time, just lift lid or press clean again.

●

When cleaning cycle is complete, machine will display

- - - -

●

Lift lid and remove tray.

●

When programmed number of cleans completed machine will drain and display END.

Automatic Shut Down
●

When the programmed number of cleaning cycles are completed the machine will automatically drain,

and display END.
●

Press and hold SHIFT & REFILL to continue cleaning or

●

Turn off at power point.

Manual Shut Down
●

Press SHIFT and DRAIN.

●

When machine has drained display will show OFF.

●

Turn off at power point.