Vizion setup procedure – TruTrak Vizion 380-385 Operation Manual User Manual

Page 11

Advertising
background image

 

Vizion  380/385  

11  

Rev  -­‐  Initial  

5. Vizion  Setup  Procedure  

 

In  the  Vizion  setup  screens,  pressing  ALT  will  advance  the  

page  to  the  next  setup  screen.    Pressing  MODE  will  return  to  the  
previous  screen.    Rotating  the  KNOB  changes  the  values.    Pressing  
the  KNOB  exits  the  setup  mode.    NOTE:    See  Section  8  for  suggested  
settings  of  many  common  aircraft.  

5.1.

Lateral  Setup

 

 

Press  and  hold  MODE  to  access  the  lateral  setup  menu.      

5.1.1. LAT  ACTIVITY  

 

Selectable  from  0  to  24.  This  setting  controls  the  “sensitivity”  of  

the  roll  servo.    A  higher  setting  will  increase  the  reaction  speed,  too  
high   will   cause   jitteriness.     A   lower   setting   will   decrease   reaction  
speed,   too   low   will   cause   sluggishness.     The   LAT   ACTIVITY   setup  
screen  is  shown  in  Figure  5.1.1a.  

 

 

Figure  5.1.1a  

5.1.2. BAUD  

 

Selectable   from   600   to   9600.     Most   GPS   settings   will   be   either  

4800  or  9600.    This  setting  must  be  matched  to  the  Baud  Rate  output  
of  the  GPS  connected  to  the  RS232  input  of  the  autopilot.    Consult  the  
setup  procedure  for  the  GPS  to  obtain  the  proper  baud  rate  setting.    
The  BAUD  setup  screen  is  shown  in  Figure  5.1.2a  

 

 

Figure  5.1.2a  

 

Advertising