Element cleaning, System inspection – Cub Cadet 7532 User Manual

Page 105

Advertising
background image

LUBRICATION/FILTERS/FRUIDS

97

Element Cleaning

Use clean, dry compressed air up
and down the pleats on the clean
side (inside) of the element.
Continue this until the element is clean.

NOTE:
1. The paper element must be

handled with care. Do not hit the

element against a hard surface.

2. Air pressure at the nozzle must not exceed 689 kPa (100 PSI).

3. It may be necessary to replace the element sooner if the time interval

between servicing becomes short indicating the element does not

respond to cleaning (soot contaminated).

System Inspection

Check the dump valve and the all hoses for cracks and wear. Replace if
needed. All the connections on the hoses must be tight. All the gaskets
must be in good condition and the bolts must be drawn up tight.

NOTE: Inspect the hoses and connections after the first 50 hours of
operation and replace when necessary.

DUMP