Chaparral FS2620R User Manual

Page 52

Advertising
background image

FS2620R Rack Model User’s Guide

3-22

Table 3-4 shows the temperature and voltage thresholds for each alarm and what to do to
resolve the problem.

To enable or disable the alarm:

1

From the System Menu, select Configuration Menu and press Enter.

The Configuration Menu screen displays.

2

Select Alarm and press Enter.

The Alarm screen displays. The current setting is marked with an * next to it.

3

Select the option you want and press Enter.

The system confirms that the changes are made.

4

Press Enter to return to the Configuration Menu.

Table 3-4. Alarm thresholds

Alarm threshold

What to do when the alarm sounds

CPU temperature

Warning—0°C to 4°C and
91°C to 100°C
Shutdown—<0°C and >100°C

!

Check the Router Administrator software to confirm
what the alarm means. See

Configuring the Router

on page 3-1

.

!

Check that the CPU fan is running and is not
obstructed.

On-board temperature

Warning—0°C to 4°C and
57°C to 61°C
Shutdown—<0°C and >61°C

!

You can feel if the fan is running by placing your hand
on the rear panel of the router near the power switch.

!

Check the ambient temperature and lower it, if needed.
Ambient temperature should be less than 45°C.

VCC voltage

Warning—5V -5.0% and +6.5%
Shutdown—5V -6.5% and +10%

!

Check the Router Administrator software to confirm
what the alarm means. See

Configuring the Router

on page 3-1

.

!

If it is a warning alarm, let the router continue to
operate.

!

If it is a shutdown alarm, turn off the power to the
router and send it for service.

12V voltage

Warning—12V -10% and +10%
Shutdown—12V -20% and +20%

!

Same as above for the VCC voltage.

Advertising