4-2

Problem: The system hangs after the “All diagnostic tests passed” message or while
scanning devices.

Solution: Follow these steps to resolve the problem:

1

Verify there are no SCSI address conflicts.

2

Check the connected SCSI devices to make sure everything is properly connected
and SCSI termination is correct. See

Restoring the Default Configuration Through

the Flash Utility

.

3

Check to make sure the devices work properly on a different router, make sure you
are not combining HVD and LVD/SE devices.

Restoring the Default Configuration Through the
Flash Utility

You can clear the router configuration and restore all router default settings without
accessing the Router Administrator software. You may want to do this if the router is not
working properly or the system hangs after the “All diagnostic tests passed” message, as
shown on the following screen.