Fig. 1—dimensional drawing, A caution, A warning – Carrier 58PAV User Manual

Page 2: Caution, Warning

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

39-7/8

11/16-

——28-1/2-

VENT CONN

13/16

7/8 DIA HOLE-

POWER ENTRY

7/8 DIA
ACCESSORY

1-3/4 DIA HOLE

GAS ENTRY

1/2 DIA HOLE

THERMOSTAT
WIRE ENTRY

SIDE INLET

5-è/8 I

H

12-5/16

5-13/16

24-5/16-

11/16

14-1/2

NOTE: 2 ADDITIONAL 7/8 DIA KNOCKOUTS

ARE LOCATED IN THE TOP PLATE

NOTE: AIR DELIVERY ABOVE 1800 CFM REQUIRES THAT BOTH SIDES OF FURNACE
BE USED, OR A COMBINATION OF 1 SIDE AND BOTTOM, OR BOTTOM ONLY FOR

RETURN AIR.

A88367

A88367

Fig. 1—Dimensional Drawing

National NFGC. Canadian installations must be installed in
accordance NSCNGPIC and all authorities having jurisdiction. For
further information, the National Fuel Gas Code is available from
National Fire Protection Association Inc. Batterymarch Park,
Quincy, MA 02269, American Gas Association, 1515 Wilson
Boulevard, Arlington, VA 22209, or from Literature Distribution.

Installation must conform to the regulations of the serving gas
supplier and the local building, heating, and plumbing codes in
effect in the area in which the installation is made, or in the
absence of local codes with the requirements of the NFGC.

A

CAUTION

Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, and unit sizing. Improper installation or
misapplication of the furnace can require excessive servicing
or cause premature component failure.

Table 2—Dimensions (In.)

UNIT SIZE

A

D

E

VENT CONN SHIP. WT

045-08

14-3/16 12-9/16 12-11/16

4

116

045-12

14-3/16 12-9/16 12-11/16

4

118

070-08

14-3/16 12-9/16 12-11/16

4

126

070-12

14-3/16 12-9/16 12-11/16

4

128

090-14

17-1/2

15-7/8

16

4

143

090-16

21

19-3/8

19-1/2

4

147

111-12

17-1/2

15-7/8

16

4

153

111-16

21

19-3/8

19-1/2

4

159

111-20

24-1/2

22-7/8

23

4

176

135-16

21

19-3/8

19-1/2

5

171

135-20

24-1/2

22-7/8

23

5

186

155-20

24-1/2

22-7/8

23

5

196

This furnace is designed for a minimum continuous return-air
temperature of 60°F db or an intermittent operation down to 55 °F
db such as when used with a night setback thermostat. Return-air
temperature must not exceed a maximum of 85°F db.

A

WARNING

Improper installation, adjustment, alteration, service, mainte­
nance, or use can cause carbon monoxide poisoning, explo­
sion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified
installer, service agency, local gas supplier, or your distribu­
tor or branch for information or assistance. The qualified
installer or agency must use only factory-authorized and
listed kits or accessories when modifying this product. A
failure to follow this warning can cause electrical shock, fire,
personal injury, or death.

NOTE;

Remove all shipping brackets and materials before

operating the furnace.

Step 1—Location

GENERAL

A

CAUTION

Do not in'stall furnace in a corrosive or contaminated atmo­
sphere. Make sure all combustion and circulating air require­
ments are met, in addition to all local codes and ordinances.

For accessory installation details, refer to the applicable instruction
literature.