Awarning, Safety precautions – Sears POWER MISER 153.335914 User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Safety Precautions

AWARNING

Improper

installation,

adjustment,

alteration,

service

or

maintenance can cause death, serious bodily injury, or
property damage. Refer to this manual for assistance or
consult

your

local

Sears

Service

Center

for

further

information.

AWARNING

WATER HEATERS EQUIPPED FOR ONE TYPE GAS
ONLY: This water heater is equipped for one type gas
only. Check the modei rating plate near the gas control
valve for the correct gas. DO NOT USE THIS WATER

HEATER WITH ANY GAS OTHER THAN THE ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
use the correct gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
your gas supplier or local utility.

AWARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ­
UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR
STORED (GARAGES, STORAGE, AND UTILITY AREAS,
ETC):

Flammable

liquids

(such

as

gasoline,

solvents,

propane (LP) or butane, etc.), all of which emit flammable
vapors, may be improperly stored or used in such areas.
The gas water heater pilot light or main burner can ignite
such vapors. The resulting flashback and fire can cause
death or serious bums to anyone in the area, as well as
property damage.

If installation in such areas is your only option, then the
installation must be accomplished in a way that the pilot

flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the changes of
flammable vapors from a floor spill being ignited, gasoline

and other flammable substances should never be stored or
used in the same room or area containing a gas water
heater or other open flame or spark producing appliance.
NOTE: Flammable vapors may be drawn by air currents
from other areas of the structure to the appliance.

AWARNING

If this water heater will be used in beauty shops, barber

shops,

cleaning

establishments,

or

self-service

laundries

with dry cleaning equipment, it is imperative that the
water heater or water heaters be installed so that com­

bustion and ventilation air be taken from outside these

areas. Refer to the “Locating The New Water Heater”
section of this manual and also the latest edition of the

National Fuel Gas Code, ANSI Z223.I, also referred to as
NFPA 54 for specifics provided concerning air required.

AWARNING

A fire can start if combustible materials such as clothing,

cleaning materials, or flammable liquids are placed against
or next to the water heater.

AWARNING

At the time of manufacture this water heater was provid­

ed with a combination temperature-pressures relief valve
certified

by

a

nationally

recognized

testing

laboratory

that maintains periodic inspection of production of listed
equipment

or

materials,

as

meeting

the

requirements

for Relief Valves and Automatic Gas Shutoff Devices for

Hot Water Supply Systems, and the latest edition of

ANSI Z2I.22 and the code requirements of ASME. If

replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as meeting the require­
ments for Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems, ANSI Z21.22 by
a nationally recognized testing iaboratory that maintains
periodic inspection of production of listed equipment or
materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure
of the water heater (ISO lbs./sq. in.) and a discharge
capacity not less than the water heater input rate as
shown on the model rating plate. (Electric heaters -
watts divided by 1000 x 3415 equal BTU/Hr. rate.)
Your local jurisdictional authority, while mandating the

use of a temperature-pressure relief valve complying

with ANSI Z21.22 and ASME, may require a valve model

different from the one furnished with the water heater.
Compliance with such local requirements must be satis­
fied by the installer or end user of the water heater with
a locally prescribed temperature-pressure relief valve
installed in the designated opening in the water heater in
place of the factory furnished valve.

For safe operation of the water heater, the relief valve
must not be removed from it’s designated opening or
plugged.

The temperature-pressure relief valve must be installed

directly into the fitting of the water heater designated

for the relief valve. Position the valve downward and pro­

vide tubing so that any discharge will exit only within 6
inches above, or at any distance below the structural
floor. Be certain that no contact is made with any live
electrical

part.

The

discharge

opening

must

not

be

blocked or reduced in size under any circumstances.

Excessive length, over 30 feet, or use of more than four

elbows can cause restriction and reduce the discharge
capacity of the valve.

No valve or other obstruction is to be placed between

the relief valve and the tank. Do not connect tubing
directly to discharge drain unless a 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam­

age, the relief valve must be allowed to discharge water
in quantities should circumstances demand. If the dis­
charge pipe is not connected to a drain or other suitable
means, the water flow may cause property damage.
The Discharge Pipe:

• Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other

restrictions.

• Must not be plugged or blocked.
• Must be of material listed for hot water distribution.
■ Must be installed so as to allow complete drainage of

both

the

temperature-pressure

relief

valve,

and

the

discharge pipe.

• Must terminate at an adequate drain.
• Must not have any valve between the relief valve and

tank.