Installation checklist, Check for leaks, Installation instructions (cont*d) – Sears POWER MISER 153.335914 User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont*d)

Installation Checklist

BEFORE LIGHTING THE PILOT:

Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks

using a match or open flame.

b. Brusn the soapy water solution on all gas pipes, joints and

fittings.

c. Check for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Rccheck for leaks.
e. Rinse off soapy solution and wipe dry.

Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain? See “Temperature-Pressure
Relief Valve” section.

Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions in the

“Installing the New Water Heater” section.

Is the water heater completely filled with water? See “Filling”
instructions in the “Installing the New Water Heater” sec­
tion.

Will a water leak damage anything? See the “Locating the
New Water Heater” section.

Is there proper clearance between the water heater and any­
thing that might catch fire? See the “Locating the New water
Heater” section.

Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”

in the “Locating the New Water Heater” section.

Is the draft hood vent piping properly secured? See “Venting”
instructions in the “Installing the New Water Heater” sec­
tion.

Is there proper clearance between the vent pipe and anything

that might catch on fire? See “Venting” instructions in the
“Installing the New Water Heater” section.

Is the vent pipe properly sloped and does the vent terminate
outdoors? See “Venting” instructions in the “Installing the
New Water Heater” section.

Do you need to call your gas company to check the gas pipe
and its hookup?

CHECK FOR LEAKS

Be sure to check all your gas pipes for leaks before lighting your
water heater. Use a soapy water solution, not a match or open

flame. Check the factory gas fittings after pilot is lit and gas con­
trol knob is still in “PILOT” position. Then, check the fittings

when the main burner is turned “ON”. Use a soapy water solu­

tion for this, too.

VENT PIPE TO

OUTDOORS

COLD

SHUTOFF _

^

TEMPERATURE-

PRESSURE RELIEF

VALVE

DISCHARGE PIPE

(Do not cap or plug)

WATBI HEATER

ttmfm

m

■wr

tu

WKiOVWY

LOAL.

________«MW

QM

■niMt

UUHR.

OMPflESSUMWWX.

150

VA.I.

PJt.1

m.c.

«,C.

MODEL RATING PLATE