TO TIME THE FEED

Before

the

machine

leaves

the

factory,

the

feed

lifting

eccentric-and-bevel-gear

and

the

feed

eccentric

are both set for

average sewing conditions;

having the

timing screw in each eccentric enter groove provided

for it in the arm shaft.

As the grooves in the arm shaft are not visible to

the adjuster, the machine pulley should be turned over

toward

operator

until

feed

lifting

eccentric

connecting

rod

A2, Fig. 41

is at its

lowest

position. Timing screw

Y,

Fig. 41

will then be on

top

of feed lifting eccentric-and-

bevel-gear. Loosen timing screw

Y

and set screw

O

and, while maintaining this position of the gear, turn

arm shaft until timing screw, as it is slowly tightened,

can be felt to drop into its groove in arm shaft. Se­

curely tighten timing screw

Y

and set screw

O.

Feed

eccentric

should

be

set

for

average

sewing

conditions, by having this timing screw

Z exactly in

line

with timing screw

Y,

as shown in

Fig. 41.

Thus,

as timing screw

Z is

tightened it will drop into its

groove in arm shaft which is in line with groove pro­

vided

for

feed

lifting

eccentric-and-bevel-gear

timing

screw

Y.

Securely tighten timing screw

Z

and the two

set screws in feed eccentric.

If for any reason, it is necessary to alter the timing

of

either

eccentric,

timing

screw

should

be

removed

and eccentric locked in desired setting by means of

set screws only.

Feed eccentric timing screw

Z, Fig. 41

appears im­

mediately

after

large

stop

screw

W, Fig. 41,

when

feed eccentric is rotated over

toward

operator.

NOTE:

Whenever the timing of the feed is changed,

sewing hook should be checked for necessary adjust­

ment also, as instructed on

page 21.