42

THE ARM SHAFT

T4

Fig. 67. Loosening the Feed Eccentric

REMOVAL-

(See Figs. 67 to 69)

7.

Loosen the four screws in the arm top cover and

remove the arm top cover.

1.

Remove the face plate.

2.

Remove the arm side shield and wick and the

thread

take-up

oil

guard,

as

instructed

on

page 36.

3.

Remove the needle bar, upper needle bar bush­

ing, presser foot and presser bar, as instructed on

page 33.

8.

Remove the oil lead that is fastened to the casting

just beneath the arm top cover.

9.

Remove the feed timing screw

Y, Fig. 67

and

loosen the set screw

O, Fig. 67,

in the feed-lifting-

eccentric-and-bevel-gear,

X3, Fig. 67.

10.

Remove the timing screw

Z

and loosen set screws

in the feed eccentric

U4, Fig. 67.

4.

Remove entire thread take-up lever assembly, as

instructed on

page 34.

11.

Remove arm shaft screw

R4, Fig, 67

from ma­

chine pulley end of arm shaft.

5.

Remove the oil-removing wick, as instructed on

pages 38

and

39.

12.

Loosen the two set screws

T4, Fig. 67

and remove

the machine pulley.

6.

Set the machine at any stitch length

except the

longest

or

the

shortest

(see

instructions

on

page 16)

to

prevent binding

of the arm shaft

during removal and replacement.

13.

Turn the needle bar crank until it is in the position

shown at

M4, Fig. 69,

to prevent crank from dis­

turbing the three wick loops in holder

W4, Fig. 69

during removal of arm shaft.

Advertising