Belt adjustment, Replacin8 needle, M]mm – SINGER W130 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Fia. 4

2. BELT ADJUSTMENT

Loosen motor bracket screw (A).

Slide motor bracket down to tighten

- up to loosen.

CAUTION : Do not tighten belt

too tight.

3. REPLACIN8 NEEDLE

1. Raise the needle bar to its highest

position. (Turn the fly wheel by

hand toward you.)

2. Loosen needle clamp screw (A) and

remove old needle.

3. Insert the needle into needle bar (B)

with the flat side of the needle toward

the fly wheel.

C.AUTION ; Be sure the needle is

all the way up. It should rest against

the needle stop pin (C).

4. Tighten the needle clamp screw se­

curely with screw driver.

C.AUTION ; Check needle and make

sure it is not bent or dull.

4

.

m]mm

b ob b i n

c a s e

Raise ihe needle bar to its highest

position. (Turn the fly wheel toward
you b}' hand.)

Open slide plate. With the left

thumb and forefinger, open the latch

(A) of the bobbin case (B).

Remove bobbin case from the spindle

post (C). (Pull to the left.)

NOTE : With the latch held open,'

the biihbin is locked inside the

bobbin case. To remove bobbin from

the bobbin case, release the latch.

Advertising