-cAN1 Nu r rtfc OTTu t f t-C

Remove plug from the power supply.

.

To remove shuttle:

Raise needle to its highest position and remove bobbin case.

Turn levers away from shuttle and lift out retaining ring and

shuttle, by grasping center pin.

Clean the reverse side of feed dog with a small brush. Remove

lint .and thread from all parts of shuttle and wipe with a lightly

oiled cloth.

To reassemble;

Hold shuttle by center pin and fit carefully back into shuttle

race, forming perfect circle with shuttle driver.

Replace retaining ring polished side out, making sure the bottom

pin fits into notch .Lock retaining ring by turning levers back into

position. Put bobbin back in .bobbin case.