4 changing the oil filter, 6 spark plug(s) – Generac DUARDIAN 04077-2 User Manual

Page 14

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section 3 — M aintenance

MAINTENANCE

Guardian Air-cooled 6 kW, 8 kW and 10 kW Generators

3.4

CHANGING

THE OIL FILTER

Change the engine oil filter as follows:

1. With the oil drained, remove the old oil filter by

turning it counterclockwise.

2. Apply a light coating of clean engine oil to the

gasket of the new filter. See section 1.7.2 (page

6) for recommended filter.

3. Screw the new filter on by hand until its gasket

lightly contacts the oil filter adapter. Then,

tighten the filter an additional 3/4 to one turn

(Figure 3.4).

4. Refill with the proper recommended oil (see sec­

tion 3.3.1). See section 1.7.2 (page 6) for oil

capacities.

5. Start the engine and check for leaks.

Figure 3.4

-

Engine Oil Filter

3.5

CHANGING THE ENGINE

AIR CLEANER

3.5.1 6 KW GENERATORS

See Figure 1.1 (page 5) for the location of your air

cleaner. Clean and reoil the foam precleaner every

three months or every 25 hours of operation,

whichever occurs first. Service the foam precleaner

more frequently if you operate the generator in

extremely dusty or dirty conditions. Use the follow­

ing procedure (Figure 3.5):

1

.

2

.

3.

4.
5.

7.

8

.

9.

Turn the two screws counterclockwise to loosen.

Remove the cover, foam precleaner and paper filter.

Remove the foam precleaner from the cover.

Wash the foam precleaner in liquid detergent

and water.

Wrap the foam precleaner in a clean cloth and

gently squeeze it dry.

Saturate the foam precleaner in clean engine

oil. Gently squeeze it in a clean cloth to remove

excess oil and to distribute oil (DO NOT TWIST).

Install the foam precleaner into the cover, fol­

lowed by the paper filter.

Install the cover, foam precleaner and paper filter.

Tighten the two screws to retain the filter in place.

See the “Service Schedule,” section 3.12 (page 15)

for air cleaner maintenance. See section 1.7.1 for

air filter replacement part number.

Figure 3.5

-

6 kW Engine Air Cleaner

♦ 3.5.2 8 KWAND 10 KW GENERATORS_____

To replace the engine air cleaner, simply loosen the

hose clamp. This air cleaner should NOT be cleaned

and reused. See section 1.7.1 for air filter replace­

ment part number.

3.6

SPARK PLUG(S)

Reset the spark plug(s) gap or replace the spark

plug(s) as necessary. See section 3.12 for mainte­

nance requirements.

1. Clean the area around the base of the spark

plug(s) to keep dirt and debris out of the engine.

Clean by scraping or washing using a wire

brush and commercial solvent. Do not blast the

spark plug(s) to clean.

2. Remove the spark plug(s) and check the condi­

tion. Replace the spark plug(s) if worn or if reuse

is questionable. See section 3.12 (page 15) for rec­

ommended Inspection.

1

S

Generac* Power Systems, Inc.

Advertising
This manual is related to the following products: