Maintenance, 2 chancing the engine oil and/or oil filter, Note – Generac Power Systems 009600-4 User Manual

Page 14: Maintaining the engine air cleaner, 1 cleaning the foam precleaner, Changing the engine oil and/or oil pdlter

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

(¿XSgiagM^ "' ' Z. '

MAINTENANCE

Section 3 - Maintenance

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

3.2

CHANCING THE ENGINE OIL

AND/OR OIL FILTER

• Change the engine oil after the first 25 hours of

operation (after the 25-hour break-in period, see
Section 2.8.5, Page 10). Thereafter, change the
oil every 100 operating hours. Change the oil more
frequently

if

operating

consistently

under

heavy

load or at high ambient temperatures.

• Change the engine oil filter after the first 25 hours

of operation, and every 100 operating hours there­
after.

To change the oil and/or oil filter, proceed as
follows:

1.

Run the engine until it is thoroughly warmed up

(at

least

five

minutes)

then

shut

OFF

the engine.

2.

With the engine still warm from running, remove

the oil drain plug (Figure 3.1). Drain the oil into
a suitable container.

3.

After the oil has drained, replace the oil drain

plug. (If only changing the oil, go to step 7.)

4.

With the oil drained, remove the old oil filter by

turning it counterclockwise (Figure 3.2 on page 12).

5.

Apply a light coating of clean engine oil to the gas­

ket of the new filter.

6.

Screw the new filter on by hand until its gasket

lightly contacts the oil filter adapter. Then, tight­
en the filter an additional 3/4 to one turn.

7.

Remove the dipstick and fill crankcase with the

proper type and amount of recommended oil (see
Section 1.6.2, Page 6). The engine crankcase can
hold about 1.4 liters. DO NOT FILL /\BOVE THE
‘TULL’ MARK.

8.

Install and tighten the dipstick before operating

the engine.

9. Start the engine and check for leaks.

NOTE:

Check the oil level and fill to the “FULL’ mark after
checking for leaks. The filter will retain some oil.

Figure 3.1

Oil Dipstick/Fill Tube and

Location of Oil Drain Plug

3.3

MAINTAINING THE ENGINE

AIR CLEANER

♦ 5.5.1

CLEANING THE FOAM PRECLEANER

Clean and re-oil the foam precleaner every three
months or every 25 hours of operation, whichever
occurs first. Service the foam precleaner more fre­
quently if operating the generator in extremely dusty
or

dirty

conditions.

Use

the

following

procedure

(Figure 3.3):

1. Turn the knob counterclockwise to loosen.

2.

Remove the cover, foam precleaner and paper fil­

ter.

3. Remove the foam precleaner from the cover.
4.

Wash the foam precleaner in liquid detergent and

water.

5.

Wrap the foam precleaner in a clean cloth and

gently squeeze it dry.

6.

Saturate the foam precleaner in clean engine oil.

Gently squeeze it in a clean cloth to remove
excess oil and to distribute oil (DO NOT T’WIST).

7.

Install the foam precleaner into the cover, fol­

lowed by the paper filter. Tabs at edges of paper

1 a Generac* Power Systems, Inc.

Advertising
This manual is related to the following products: