GENERAL

INFORMATION

Section 1 - General Information

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

Figure 1.1

-

Connection for 120 Volts Only

Fuel Consumption

(gph/ibs.ph)

Figure 1.2 - Connection for 120/240 Volts

1.6

SPECIFICATIONS

♦ 1.6.1

FUEL REQUIREMENTS

This generator is equipped with a gasoline fuel system

as standard equipment. Specific installations may pro­

vide either a separate fuel tank for the generator, or the
generator may “share” the vehicle engine’s fuel tank.

Model

No Load

1/2 Load

Full Load

PrimePact 66G

0.33

0.59

0.99

PrimePact 66LP

0,47/2.01

0.85/3.62

1,66/7.05

NOTE

Some installations using a “shared” fuel tank may
have a generator fuel pickup tube that is shorter
than the vehicle engine’s pickup tube. Such an
arrangement causes the generator engine to “run
out of gas” while adequate fuel for the vehicle
remains in the tank.

To reduce lead and carbon deposits use high quality
UNLEADED

gasoline

with

the

generator.

Leaded

REGULAR grade gasoline is an acceptable substitute.

NOTE:

Using unleaded gasoline contributes to longer engine

valve life by reducing lead and carbon deposits.

------ Jk CAUTION Jk-----------

A

Generac does not recommend using any

gasoline containing alcohol (such as "gasohol").
If you use any gasoline containing alcohol, it
must not contain more than 10 percent ethanol,
and it must be removed from the generator
during storage. Do

NOT

use any gasoline

containing methanol. If you use gasoline with
alcohol, inspect more frequently for fuel leaks
and other abnormalities.

♦ 1.6.2 ENGINE OIL REQUIREMENTS_______________

Use only high quality detergent oil classified “For
Service SF” and with an oil viscosity rating of SAE

lOW-30 oil. Do not pour in any additives to the rec­

ommended

oil.

Engine

crankcase

capacity

is

1.4

liters. See Section 3.2 on page 11 for oil level check
and filing procedures.

♦ 1.6.3 GENERATOR SPECIFICATIONS

SERIES

PRIMEPACT 66G

PRIMEPACT 66LP

Rotor RPM

3600

3600

Rotor Poles

2

2

Engine RPM

2700

2700

Rated Max. Continuous AC Output*

6600 watts (6.6 kW)

6200 watts (6.2 kW)

Voltage*

120

120

Rated Max. Continuous Current*

55.0 AC ampst

51.7 AC amps N

Phase

1

1

Frequency

60 Hertz

60 Hertz

Battery Charging Current (Max.)

2

amps (trickle charge)

2

amps (trickle charge)

Weight

213 pounds

216 pounds

Length

25 inches

25.75 inches

Width

18,5 inches

18.5 inches

Height

15.75 inches

15.75 inches

* All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output

t Rated maximum continuous current at 240 volts is 27,5 amps,

N Rated maximum continuous current at 240 volts is 25,8 amps.