Generac Power Systems 009600-4 User Manual

Page 27

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Section 6 - Installation

INSTALLATION

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

Vapor seal all compartment seams and joints.

Over the galvanized steel lining, install a combination

of acoustical materials as mentioned in Section 6.2.3.

DANGER

Figure 6.7 - Typical Noise Abatement

To prevent fire or

explosion,

do not install any

insulation or other absorbent materials on the
interior or underside of the compartment floor.

Seal all compartment door edges to prevent noise

leakage around the door perimeter.

Line the compartment door interior (except for air

openings)

with

suitable,

fireproof

sound

insulation

(such as 1 -inch (25 mm) thick fiberglass with a 2-

pound density).

Figure 6.8

Compartment Floor Cutout

Advertising