NewAir AI-400 Series User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Only Ice-making only is not

working

Ice Button and Ice

indicator on the

control panel

Ice-making function is not

turned on by the button.

Press the Ice-making button

Cold water function

Both

Ice-making

and

cold

water

functions

are

running

together

Wait a few more minutes and stop

the Cold Water function first

Compressor is not running or

suddenly stops

Main power supply

Voltage too low

Contact an electrician or the

electricity department

Ventilation opening

blocked

Blocked

Remove

the

substance

blocking

the

opening

Clearance around

the unit

Too small clearance or bad air

circulation

Leave enough space around the unit

(Min. 15 cm)

Condenser

Too dirty, produce overheated

Clean

Cooling system

Refrigerant

over

charged

or

leaked

Contact with qualified serviceman to

repair it

Compressor and

accessories

Breakdown

Cali

a

serviceman

to

check

and

repair

Warm

indicator

illuminates

and buzzes

Water bottle

There is no water.

Replace with

a new bottle full of

water

Warm indicator flashes on the

control panel

Ice-making box in

the ice-making

chamber

The ice making box is clogged

by

ice

or

some

other

mechanism

Stop the unit and allow some time

for the clogged ice to melt

Water leaks from the taps or

the faucet

Water faucet button

The water faucet button may be

clogged

Check it and let the button go out

Water faucet

The

water

faucet

has

been

damaged.

Call your service or sales agent for

replacement information

Water is dripping out of the

water dispenser and onto the

floor.

Water bottle

The

bottle

may

have

small

pinholes

Change to a new bottle

Water drain caps on

the back

Loose

Tighten

these

completely

and

check

the

sealing

silicon

material

inside

the drain cap to make sure it is not

torn or damaged. If so, change to

new drain caps

Noise occurs

Floor

The appliance is not level.

Install it evenly and lock the unit

Locating position

Contact with other products

Move it away from other products

14