2.4 Run a Sample Program

If you already have Dynamic C installed, you are now ready to test your programming
connections by running a sample program. Start Dynamic C by double-clicking on the
Dynamic C icon on your desktop or in your

Start

menu. Dynamic C uses the serial port

specified during installation.

If you are using a USB port to connect your computer to the BL1810, click on the

Commu-

nications

tab and verify that

Use USB to Serial Converter

is selected to support the USB

programming cable. Click

OK

.You may have to determine which COM port was assigned to

the RS-232/USB converter. Open

Control Panel > System > Hardware > Device Man-

ager > Ports

and identify which COM port is used for the USB connection. In Dynamic C,

select

Options > Project Options

, then select this COM port on the

Communications

tab, then click

OK

. You may type the COM port number followed by

Enter

on your com-

puter keyboard if the COM port number is outside the range on the dropdown menu.

Find the file

PONG.C

, which is in the Dynamic C

SAMPLES

folder. To run the program,

open it with the

File

menu, compile it using the

Compile

menu, and then run it by selecting

Run

in the

Run

menu. The

STDIO

window will open on your PC and will display a small

square bouncing around in a box. This program shows that the CPU is working.

2.4.1 Troubleshooting

If Dynamic C cannot find the target system (error message

"No Rabbit Processor

Detected."

):

Check that the BL1810 is powered correctly — the AC adapter should be connected to

header J1 on the Jackrabbit board

and should be plugged in to a wall outlet.

Check both ends of the programming cable to ensure that they are firmly plugged into
the PC and that the

PROG

connector, not the

DIAG

connector, is plugged in to the

programming port on the BL1810 with the colored side lined up with pin 1.

Ensure that the BL1810 is firmly and correctly installed in its sockets on the Prototyp-
ing Board.

Select a different COM port within Dynamic C. From the

Options

menu, select

Project Options

, then select another COM port from the list on the

Communications

tab, then click

OK

. Press

<Ctrl-Y>

to force Dynamic C to recompile the BIOS.

If a program compiles and loads, but then loses target communication before you can
begin debugging, it is possible that your PC cannot handle the default debugging baud rate.
Try lowering the debugging baud rate as follows.

Locate the

Serial Options

dialog in the Dynamic C

Options > Project Options >

Communications

menu. Choose a lower debug baud rate, then click

OK

.