Venting installation instructions – Desa (V)T32EN SERIES User Manual

Page 15

Advertising
background image

www.desatech.com

111987-01D

15

Figure 20 - Installing Firestop

If area above is a living space, install
firestop below framed hole.

If area above is an attic or insulated area,
install firestop above framed hole.

7. Twist-lock the vent cap onto the last section

of vent pipe.

Note:

If the vent pipe passes through any occupied

areas above the first floor, including storage spaces

and closets, you must enclose pipe. You may

frame and sheetrock the enclosure with standard

construction material. Make sure and meet the

minimum allowable clearances to combustibles.

Do not fill any of the required air spaces with

insulation.

VENTING INSTALLATION

INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 21 through 24 show four different con-

figurations for vertical termination.

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H

1

) +

Horizontal (H

2

)

5' min.

' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

0' max.

8' max.

Figure 21 - Vertical Venting

Configuration Using Two 90° Elbows

with Two Horizontal Runs (Vertical

Round High Wind Termination Shown)

Note: Install restrictor

into inner collar of

fireplace as shown.

45° Elbow

Venting with One 90° Elbow
Vertical (V)

Horizontal (H)

5' min.

' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

0' max.

8' max.

Figure 22 - Vertical Venting

Configuration Using One 90° Elbow

(Vertical Round High Wind Termination

Shown)

45° Elbow

Note: Install restrictor into
inner collar of fireplace as
shown.