Venting installation instructions – Desa (V)T32EN SERIES User Manual

Page 16

Advertising
background image

www.desatech.com

111987-01D

16

VENTING INSTALLATION

INSTRUCTIONS

Continued

Note: Install
restrictor into
inner collar of
fireplace as
shown.

Venting with Two 90° Elbows

vertical (v

1

)

Horizontal (H)

5' min.

6' max.

6' min.

1' max.

7' min.

18' max.

8' min.

0' max.

Note: Vertical (V

1

) + Vertical (V



) = 40' max.

Figure 23 - Vertical Venting

Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination

Shown)

45° Elbow

Vertical Venting

V = 40' max.

Figure 24 - Vertical Venting

Configuration With No Horizontal Run

(Vertical Round High Wind Termination

Shown)

Note: Install
restrictor into
inner collar of
fireplace as
shown.

45° Elbow

HIGH ALTITUDE INSTALLATION

Your DESA direct-vent fireplace has been tested and

approved for elevations from 0-2,000 feet (USA)

and elevations from 0-4,500 feet (Canada).

When installing this fireplace at an elevation

above 2,000 feet (in the USA), you may need to

decrease the input rating by changing the existing

burner orifice to a smaller size. Reduce input 4%

for each 1,000 feet above sea level. Check with

your local gas company for proper orifice size

identification.

When installing this fireplace at an elevation

above 4,500 feet (in Canada), check with local

authorities.
IMPORTANT:

For horizontal installations

above 2,000 feet, it is recommended that a 12"

extension pipe be added before starter elbow

(see Figure 25, page 17 ).