Venting installation instructions – Desa (V)T32EN-A Series User Manual

Page 11

Advertising
background image

11

11

www.desatech.com

116647-01A

SNORKEL TERMINATION INSTALLATION
Recommended Applications:
• Installations requiring a vertical rise on building exterior
• Any installation using snorkel termination to achieve one foot above ground
Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termina-

tion below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back fill

around snorkel termination.

VENTING INSTALLATION

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Snorkel

Termination

12"

Minimum

Snorkel

Termination

Wall

Firestop

90° Elbow

45°

Elbow

Figure 16 - Snorkel Termination Configurations for Below Ground Installation

12"

Minimum

12"

Minimum

Snorkel

Termination

Adequate

Drainage

Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS
The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.

Venting with Two 90° Elbows

Horizontal (H

1

) +

Vertical (V)

Horizontal (H

1

) Horizontal (H

2

)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' max.

20' max.

20' max.

8' max.

20' max.

45° Elbow