Venting installation instructions – Desa (V)T32EN-A Series User Manual

Page 12

Advertising
background image

12

www.desatech.com

116647-01A

INSTALLATION FOR VERTICAL TERMINATION

Note:

Vertical restrictor must be installed in all vertical installations.

1. Determine the route your vertical venting will take. If ceiling

joists, roof rafters or other framing will obstruct the venting

system, consider an offset (see Figure 19) to avoid cutting

load bearing members. Note: Pay special attention to these

installation instructions for required clearances (air space)

to combustibles when passing through ceilings, walls, roofs,

enclosures, attic rafters, etc. Do not pack air spaces with insu-

lation. Also note maximum vertical rise of the venting system

and any maximum horizontal offset limitations.

2. Set the fireplace in desired location. Drop a plumb line down

from the ceiling to the position of the fireplace exit flue. Mark

the center point where the vent will penetrate the ceiling. Drill

a small locating hole at this point.

Drop a plumb line from the inside of the roof to the locating

hole in the ceiling. Mark the center point where the vent will

penetrate the roof. Drill a small locating hole at this point.

Figure 19 - Offset with Wall Strap and 45° Elbows

Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows with Termination at 90° with Fireplace

VENTING INSTALLATION

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)
Installation for Vertical Termination

Venting with Two 90° Elbows

Horizontal (H

1

) +

Vertical (V)

Horizontal (H

2

)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

20' max.

20' max.

45° Elbow

45° Elbow

Wall Strap

Roof Flashing

Ceiling Firestop