Datalogic Scanning DS1500 User Manual

Page 27

Advertising
background image

INSTALLATION

2

RS485 Half-Duplex Interface


The RS485 half-duplex (3 wires + shield) interface is used for polled communication
protocols.

It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 2.6.3
and 2.6.4) exploiting a proprietary protocol based on polled mode called MUX32
protocol, where a master device polls slave devices to collect data.

The connector pinout follows:

Pin Name Function

6

RTX485+

RS485 transmit/receive data +

2

RTX485-

RS485 transmit/receive data -

4 SGND signal

ground


RTX485 +

6

RTX485 -

2

RTX485 +

RTX485 -

4

SGND

MULTIPLEXER

RS485REF

DS1500

13

SHIELD

Earth Ground

Figure 9 - RS485 Half-duplex Connections


This interface is forced by software when the protocol selected is MUX32 protocol.

In a Multiplexer layout or for slaves, the Multidrop address must also be set via the
serial channel by the WinHost utility or by ESC sequences.

15