6 relay output (usb-7250 only), Relay output (usb-7250 only), Figure 3-11 – ADLINK USB-7250 User Manual

Page 45: Usb-7230 isolated output, Figure 3-12, Form c relay, Figure 3-13, Form a relay

Advertising
background image

Operations

35

USB-7230/7250

Figure 3-11: USB-7230 Isolated Output

3.6 Relay Output (USB-7250 only)

USB-7250 provides Form C and Form A relays, with channels 0 to
3 Form C, and 4 to 7 form A, as shown.

Figure 3-12: Form C Relay

Figure 3-13: Form A Relay

Form C relays have NC (Normal Close), NO (Normal Open), and
COM (Common) contacts. The COM terminal, located in the cen-
ter,must contact either the NO pole or NC pole. When the control
bit is high (1), contact is made between the COM terminal and NO
pole, and if low (0), between the COM terminal and NC pole. Form

PHOTO COUPLER

5V

DO_n

Controller

(n=0~15)

VDD

DOn

IGND

IGND

LOAD

5~35V