Installation ● 5

2

Installation

The chapter depicts the procedure of installation PXIS-2630 series chassis.

2.1 Power Budget Consideration

Prior to installing any modules into the PXIS-2630 series chassis, please
calculate the system power requirement. The power budget for every DC
power sources shall also be checked, including +5V, +3.3V, +12V, -12V
supply rail. Please refer to Appendix A.2 for the maximum usable power.

2.2 Step for Installation

Follow the step to power on the chassis.

1. Make sure the power switch is in the OFF position.

2. Plug in the AC power cord.

3. Install your controller. Please check the ejector/injector handle

is pushed down. Align the controller edge to the “RED” card
guide, sliding in to the rear of the chassis. Push up on the
ejector/injector handle to fully inject the card into the chassis.
Secure the screws on the module’s front panel.

4. Install peripheral modules if any.

5. Press the power switch on the front panel to power on the

chassis.

6. Check the LED to make sure the power input is ready. There

are four Green LED indicators (3.3V, 5V, +12V, and -12V). The
four LEDs will light when power turn on. The fans should
become operational as well.

Note: If the chassis does not power on, see Chapter 4, Troubleshooting and

Preventative Maintenance.