ADLINK PXIS-2630 Series User Manual

Page 27

Advertising
background image

Specifications

• 21

SPECIFICATIONS:

ġ

• Temperature

range: Operating 0°C to 40°C.

•

Hold up time: 16ms MINIMUM at full load & normal input voltage.

•

Dielectric Withstand: Input / Output 1500 VAC for 1 second.
Input to Frame Ground 1500 VAC for 1 second.

•

Efficiency: 68% Typical.

•

Power good signal: ON DELAY 100 ms to 500 ms, OFF DELAY 1 ms.

•

Over load protection: 130 +/- 20%.

•

Over voltage protection: +5V

Îġ5.7V ~ 6.5V, 3.3V Îġ3.9 ~ 4.3V, 12V

Îġ13.6 ~ 15V.

•

Short circuit protection: +5V, -5V, +12V, -12V, +3.3V.

•

EMI noise filter: FCC Class B, CISPR22 Class B.

•

Safety: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950.

•

Remote ON / OFF control. The unit shall accept a logic open collector
level which will disable/enable all output voltages (exclude +5V
standby), As logic level is low, outputs voltage were enable, as logic
level is high, outputs voltage was disable.

•

3.3V/5V Remote Sensing.

•

Cooling: one 80mm ball bearing DC FAN.

•

Dimension: 140 (D) x150 (W) x 86 (H) mm (PS/2).

ġ

•

Active power factor correction meets IEC-1000-3-2 Class D.

ġ

•

Advance thermal & acoustics control features.

Advertising