3 physical, 4 environment, 5 shock and vibration – ADLINK PXI-3950 User Manual
Page 20: 6 certification, Physical, Environment, Shock and vibration, Certification
Advertising
![background image](/manuals/733433/20/background.png)
6
Introduction
1.3.3 Physical
1.3.4 Environment
1.3.5 Shock and Vibration
1.3.6 Certification
Electromagnetic compatibility
CE Compliance
The PXI-3950 meets the essential requirements of applicable
European Directives.
Dimensions
3-slot 3U PXI module
Slot requirements
1 system slot and 2 controller expansion slots
Weight
0.9 kg
Operating temperature
0 to 55°C
Storage temperature
-20 to 80°C
Relative humidity
5 to 95%, non-condensing
Functional shock
30 G, half-sine, 11 ms pulse duration
Random vibration
Operating
5 to 500 Hz, 0.5 Grms, 3 axes
Non-operating
5 to 500 Hz, 2.46 Grms, 3 axes
EMC/EMI:
CE, FCC Class A