Figure 3-5, Analog trigger conditions – ADLINK PCIe-9529 User Manual

Page 34

Advertising
background image

24

Operations

the specified trigger level to a voltage exceeding the
specified trigger level.

Z

Negative-slope trigger: The trigger event occurs when
the analog input signal changes from a voltage exceed-
ing the specified trigger level to a voltage lower than the
specified trigger level.

Figure 3-5: Analog Trigger Conditions

Trigger signal can be chosen from among CH0, CH1,

CH2,CH3, CH4, CH5, CH6 and CH7 during use of an external
analog trigger source. The trigger level can be set by software
with 24-bit resolution, with characteristics as shown.

Table 3-4: Preferred Characteristics for Analog Triggers

Trigger Level
Setting (Hex)

Trigger Voltage
(-10V to +10V Range)

Trigger Voltage
(-1V to +1V Range)

7FFFFF

9.99999881 V

0.999999881 V

7FFFFE

9.99999762 V

0.999999762 V

1

1.19 μV

0.119 μV

0

0V

0V

FFFFFF

-1.19 μV

-0.119 μV

800001

-9.99999881 V

-0.999999881 V

800000

-10 V

-1 V

Trigger Level

Positive-Slope Trigger Event

Occurs

Negative-Slope Trigger

Event Occurs

Analog

Signal

Advertising