3 trigger input/strobe output connector, Trigger input/strobe output connector, Figure 1-13: trigger input/strobe output connector – ADLINK EOS-4000 User Manual
Page 29
Advertising
![background image](/manuals/733456/29/background.png)
Introduction
17
EOS-4000
1.6.3
Trigger Input/Strobe Output Connector
The EOS-4000 features a 2-CH trigger input and strobe output on
the rear panel, based on an onboard digital I/O card supporting
features as follows.
Table 1-11: Trigger Input/Strobe Output Specifications
Figure 1-13: Trigger Input/Strobe Output Connector
Line/Area Trigger Input
Item
Min.
Max.
Test Conditions
Input high threshold
+2.0V
+5.5V
Ambient temperature: 25°C
Input low threshold
0V
+0.8V
Input signal frequency N/A
2MHz
Strobe Output
Item
Min.
Max.
Test Conditions
High output voltage
+3.8V
+5V
Typical output current: +/- 24mA
Low output voltage
0V
+0.4V
1
8
9
15
Advertising