Command Set
• 63
Note : When you want to change the checksum or baud rate then the
DEFAULT* pin should be grounded at first.
@Example
User command:
%0130400600<CR>
Response:
!30<CR>
Item Meaning
Description
%
(Leading Code)
Command leading code.
01
(OldAddr)
Original address ID is 01H.
30 (NewAddr)
New address ID is 30H 
(Hexadecimal). 
40
(TypeCode)
Digital I/O module.
06
(BaudRate)
Baud rate is 9600.
00
(CheckSumFlag)
00 means checksum is disable.
<CR> Carriage
return 0x0D.
Code
Baudrate
03 1200
bps
04 2400
bps
05 4800
bps
06 9600
bps
07 19200
bps
08 38400
bps
09 115200
bps
Table 0-1 Baud rate setting code
Table 0-2 Check sum flag setting
7
6
5
4
3
2
1
0
Reserved 
Must to be 0 
Checksum 
0 : disable 
1 : enable 
Reserved 
Must to be 000000 