Serial port mode, Flow control, Redirection after bios post – ADLINK cPCI-3965 User Manual

Page 75: Terminal type, Vt-utf8 combo key support, Sredir memory display delay

Advertising
background image

BIOS Setup

61

cPCI-3965

Note:

If you have changed the resource assignment of the serial

ports in Advanced> SuperIO Configuration, you must Save

Changes and Exit, reboot the system, and enter the setup

menu again in order to see those changes reflected in the

available Remote Access options.

Serial Port Mode

Select the baud rate you want the serial port to use for console

redirection. The options are 115200 8,n,1; 57600 8,n,1; 19200

8,n,1; and 09600 8,n,1.

Flow Control

Set this option to select Flow Control for console redirection.

The settings for this value are None, Hardware, or Software.

Redirection After BIOS POST

This option allows you to set Redirection configuration after

BIOS POST. The settings for this value are Disabled, Boot

Loader, or Always.

X

Disabled:

Set this value to turn off the redirection after POST

X

Boot Loader:

Set this value to allow the redirection to be

active during POST and Boot Loader.

X

Always:

Set this value to allow the redirection to be always

active.

Terminal Type

This option is used to select either VT100/VT-UTF8 or ANSI

terminal type. The settings for this value are ANSI, VT100, or

VT-UTF8.

VT-UTF8 Combo Key Support

This option enables VT-UTF8 Combination Key Support for

ANSI/VT100 terminals. The settings for this value are Enabled

or Disabled.

Sredir Memory Display Delay

This option gives the delay in seconds to display memory infor-

mation. The options for this value are No Delay, Delay 1 Sec,

Delay 2 Sec, or Delay 4 Sec.