3 temperature alarm, 4 fan specifications, Mechanical drawing – ADLINK cPCIS-ET2600 Series User Manual
Page 40: Temperature alarm, Fan specifications
 
34
•
Cooling System
4.3 Temperature
Alarm
When the subsystem's internal temperature exceeds 50°C, the TEMP LED 
will flash and an audible warning will be heard. To reset the alarm and 
disable the audible warning, press the Alarm RST button. 
In order to protect the system from damage resulting from overheating, it 
should be shut down immediately. Inspect the operating environment for 
causes of the overheating condition. After the system has cooled down 
sufficiently, power it up and be observant of any future temperature alarm 
conditions. 
4.4 Fan
Specifications
•
Model: ADDA AD0812XB-D93GP
•
Dimensions: 80 x 80 x 15mm.
•
Weight: 63 Gram.
•
Type: 12VDC brush-less with ball bearing motor.
•
Rated voltage: 12V @ 0.38A.
•
Rated power: 4.56 W each.
•
Fan speed: 4000 RPM.
•
Maximum Air flow: 46.3 CFM each (when zero static pressure).
•
Noise: 42.7 dBA each.