3 temperature alarm, 4 fan specifications, Mechanical drawing – ADLINK cPCIS-ET2600 Series User Manual

Page 40: Temperature alarm, Fan specifications

Advertising
background image

34

Cooling System

4.3 Temperature

Alarm

When the subsystem's internal temperature exceeds 50°C, the TEMP LED
will flash and an audible warning will be heard. To reset the alarm and
disable the audible warning, press the Alarm RST button.

In order to protect the system from damage resulting from overheating, it
should be shut down immediately. Inspect the operating environment for
causes of the overheating condition. After the system has cooled down
sufficiently, power it up and be observant of any future temperature alarm
conditions.

4.4 Fan

Specifications

Model: ADDA AD0812XB-D93GP

Dimensions: 80 x 80 x 15mm.

Weight: 63 Gram.

Type: 12VDC brush-less with ball bearing motor.

Rated voltage: 12V @ 0.38A.

Rated power: 4.56 W each.

Fan speed: 4000 RPM.

Maximum Air flow: 46.3 CFM each (when zero static pressure).

Noise: 42.7 dBA each.

Mechanical Drawing